Main functions:
Application: suitable for aerospace, petrochemical industry, machinery manufacturing, metal materials and products, wire and cable, rubber and plastic, paper and color printing packaging, adhesive tapes, bags handbags, textile, food, pharmaceutical and other industries. Mainly applicable to metal and non-metallic materials testing, such as rubber, plastics, wire and cable, fiber optic cable, seat belts, belts, leather belt composite materials, plastic material, waterproofing materials, non-ferrous metal wire, steel, copper, profile, spring steel, bearing steel, stainless steel, and other high hardness steel), castings, steel plates, steel belt, the material such as tensile, compression, and a pull, pressure, bending, shear, peel, tear, and adhesion two-point extension (match) extensometer and other test.
Design criteria:
GB/T 16491、GB/T 1040、GB/T 8808、GB/T 13022、GB/T 2790、GB/T 2791、GB/T 2792、GB/T 16825、GB/T 17200、GB/T 3923.1、GB/T 528、GB/T 2611、GB/T 6344、GB/T 20310、GB/T 3690、GB/T 4944、GB/T 3686、GB/T 529、GB/T 6344、GB/T 10654、HG/T 2580、JC/T 777、QB/T 2171、HG/T 2538、CNS 11888、JIS K6854、PSTC-7、ISO 37、AS 1180.2、BS EN 1979、BS EN ISO 1421、BS EN ISO 1798、BS EN ISO 9163、DIN EN ISO 1798、GOST 18299、DIN 53357、ISO 2285、ISO 34-1、ISO 34-2、BS 903、BS 5131、DIN EN 12803、DIN EN 12995、DIN53507-A、DIN53339、ASTM D3574、ASTM D6644、ASTM D5035、ASTM D2061、ASTM D1445、ASTM D2290、ASTM D412、ASTM D3759/D3759M
Technical parameters:
Capacity to choose 5, 10, 20, 50, 100, 200, 500, 1000, 2000, 1000 KGF choose 1 set
Measurement accuracy is better than that of plus or minus 0.5%
Load resolution 1/200000
Deformation measurement resolution of 0.001 mm
Effective load range of 0.5 ~ 100% F.S
Deformation accuracy is superior to the value plus or minus 0.5%
Test the speed range of 0.01 ~ 1000 mm/min, can be arbitrarily set
Test range of maximum 1000 mm, excluding fixture
∝ before and after the test space effectively, around 400 mm
Unit shows: KGF, N, LBF;
Stop on the way, the lower security Settings, the emergency stop button, the program strength and extension set, specimen damage sensor
Power frequency conversion motor
Power supply 1 ph, AC220V, 50/60 hz, 15 a or specified
Fixture: standard tensile fixtures
Host: (about) 300 Kg in weight