The main function:
The tester is used to test molding bags and other materials resistant to the extent of the impact test. The impact of the weight of the instrument at a predetermined head, adjust certain height, so that free fall against the specimen, depending on the extent of the damage.
Standard: The instrument complies with QB / T2155-2010 standard, according to QB / T 2918 luggage drop hammer impact test methods.
Technical Parameters:
Maximum height: 2000mm
Falling ball control method: DC electromagnetic control
Impact head weight: 2000g, 3000g, 4000g, 50000g, one each
Impact head size: cylinder diameter 100 ± 2mm, bottom radius of 50 ± 2mm
Volume (approximately): 120cm × 120cm × 210cm
Power: 1∮ AC 22V 2A